Characteristics

Construction
Type : electrical wire
Core : • reinforced version: stranded or solid tin plated or bare copper conductor (strands > .015 in) (other material available on request)
• reinforced & jacketed version: stranded or solid tin plated or bare copper (strands > .015 in) (other material available on request)
Insulation : • reinforced version: extruded silicone rubber insulation
• reinforced & jacketed version: extruded silicone rubber inner insulation / extruded silicone rubber outer insulation
Reinforcing braid : • reinforced version: coated fiberglass braid
• reinforced & jacketed version: fiberglass braid
Production
Standard products : standard insulation colors: white, black, brick red and colorless
stranding of conducting conductors – please contact us
surface marking
Application
Use : internal wiring of electronic ignition application in Gas Ranges or Gas or Fuel Oil burner systems where protected from damage during handling, installation and servicing of the appliance
General characteristics
Benefits : • Good resistance to thermal shock
• Good UV resistance
• Improved mechanical resistance
Thermal characteristics
Operating temperature : -60°C to +200°C
Electrical characteristics
Voltage ratings : 10,000 V Pulse
Approvals - Standards
Compliance UL/cUL : file E101965
Reinforced: UL 3304
Reinforced & jacketed: UL 3573